Page 101 - GuideFWA
P. 101
IN TER FER EN C E AN ALYSIS C ASE
Param eter Interfering TX Victim R X
System IS95 DECT
D evice B ase Station B ase Station
Frequency D ata
1850-1990 M H z Frequency Block A (upperpart) 1910 -1930 M H z
W orking Frequency (M H z)
N um berofguard channels 1931,250 1928,448
G uard Band betw een channeledges (KH z)
TX/R X frequency O ffset(KH z) 00
1313
2802,0
System D ata
TX Pow er(dBm ) 43
R X sensitivity (dBm ) **See N ote ** -76
10
Specific C /Ivalue forR eceiverVictim System (dB)
Antenna and FeederD ata
Antenna heigth (m ) 25,0 15,0
Antenna G ain (dBi) 17,0 12,0
Antenna H orizontalBeam w idth (º) 105 120
Antenna VerticalBeam w idth (º) 17
Antenna D ow ntilt(º) 9
-3 -7
FeederLosses (dB) 2,0 1,0
O therC alculation Inputs
Im provem enton TX m ask specification (dB) 0,0
Allow ed R x D esensitization (dB) 0,3
N ote:This is the R eceiverSensitivity w ith R ayleigh Fading (10 dB )
R ESU LTS
R equired distances forD esentization equalto 0,25 dB : R eq.distance (m )
W hen both TX and R X are on R X and TX antenna 3dB-beam w idth 1248,2
W hen only R X is on TX antenna 3dB-beam w idth 0,4
W hen only TX is on R X antenna 3dB-beam w idth 0,4
W hen both TX and R X are outofR X and TX antenna 3dB-beam w idth 0,0
R equired distances w hen TX and R X antennae are on-beam ,fordifferentD esentization:
Desentization (dB)3,00 D esentization (dB ) R eq.D istance (m ) ###
2,50 ###
2,00 500,0 1000,0 1500,0 2000,0 2500,0 3000,0 0,3 1248,2 ###
1,50 Required Distance (m) ###
1,00 0,25 2609,3 ###
0,50 0,50 1818,3 ###
0,00 0,75 287,6 ###
1,00 ###
0,0 1,25 2,5 ###
1,50 2,2 ###
1,75 2,0
2,00 1,8
2,25 1,7
2,50 1,5
2,75 1,4
3,00 1,3
1,3
Inter-American Telecommunication Commission 87