IN TER FER EN C E AN ALYSIS C ASE
Param eter Interfering TX Victim R X
System DECT PC S1900
D evice B ase Station B ase Station
Frequency D ata
1850-1990 M H z Frequency Block 1910 -1930 M H z C (low erpart)
W orking Frequency (M H z)
N um berofguard channels 1912,896 1909,800
G uard Band betw een channeledges (KH z)
TX/R X frequency O ffset(KH z) 00
2132
3096,0
System D ata
TX Pow er(dBm ) 24
R X sensitivity (dBm ) **See N ote ** -104
9
Specific C /Ivalue forR eceiverVictim System (dB)
Antenna and FeederD ata
Antenna heigth (m ) 15,0 25,0
Antenna G ain (dBi) 12,0 17,0
Antenna H orizontalBeam w idth (º) 120 105
Antenna VerticalBeam w idth (º) 17
Antenna D ow ntilt(º) 9
-7 -3
FeederLosses (dB) 1,0 2,0
O therC alculation Inputs
Im provem enton TX m ask specification (dB) 0,0
Allow ed R x D esensitization (dB) 1,0
N ote:This is the R eceiverSensitivity w ith R ayleigh Fading (7 dB )
R ESU LTS
R equired distances forD esentization equalto 1 dB : R eq.distance (m )
W hen both TX and R X are on R X and TX antenna 3dB-beam w idth 1122,7
W hen only R X is on TX antenna 3dB-beam w idth 0,3
W hen only TX is on R X antenna 3dB-beam w idth 0,3
W hen both TX and R X are outofR X and TX antenna 3dB-beam w idth 0,0
R equired distances w hen TX and R X antennae are on-beam ,fordifferentD esentization:
Desentization (dB)3,00 D esentization (dB ) R eq.D istance (m ) ###
2,50 ###
2,00 500,0 1000,0 1500,0 2000,0 2500,0 1,0 1122,7 ###
1,50 Required Distance (m) ###
1,00 0,25 2293,6 ###
0,50 0,50 1598,3 ###
0,00 0,75 1285,9 ###
1,00 1122,7 ###
0,0 1,25 989,2 ###
1,50 889,5 ###
1,75 811,0
2,00 747,0
2,25 693,4
2,50 647,6
2,75 607,8
3,00 572,7
46